I am wondering what measures can be taken to avoid x-million
dollar damage by lightning on local network cables like
Ethernet.
*
*
*
*****
*
*
*
***
**
*
The standard says : the shield conductor of each coaxial cable
segment shall make electrical contact with an effective EARTH-
reference at ONE point. A lightning on the other side of the
segment can destroy a lot of interface units and possibly more.
We at OCE have a lot of buildings with Ethernet in between.
An expensive solution is using optical ways to seperate.
I know there are 'spike-' or 'surge-' suppressors to be put
in coaxial cables. The one I know are for IBM (93 ohm) cabling.
Does anyone know such suppressors for Ethernet cable (50 ohm) ?
What about reflections with these suppressors ?
All ideas to avoid lightning problems on networks are welcome!
Ruurd van der Meer OCE NEDERLAND BV
Netherlands// Venlo
*****************************************************************
Technical Details
Message-ID:
<84@oce-rd2.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!watmath!clyde!burl!ulysses!mhuxr!mhuxn!ihnp4!qantel!lll-crg!seismo!mcvax!oce-rd1!oce-rd2!rvdmShow Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.1 6/24/83 (MC840302); site oce-rd2.UUCP Path: arc1-ca.pugleaf.net!utzoo!watmath!clyde!burl!ulysses!mhuxr!mhuxn!ihnp4!qantel!lll-crg!seismo!mcvax!oce-rd1!oce-rd2!rvdm From: rvdm@oce-rd2.UUCP (Ruurd van der Meer) Newsgroups: net.lan,net.dcom Subject: Ethernet DAMAGE by hazardous voltages (e.g. lightning) Message-ID: <84@oce-rd2.UUCP> Date: Wed, 27-Nov-85 11:26:34 EST Article-I.D.: oce-rd2.84 Posted: Wed Nov 27 11:26:34 1985 Date-Received: Fri, 29-Nov-85 21:41:11 EST Organization: OCE R&D dept., Venlo, The Netherlands Lines: 35