Rich Grise wrote: > On Mon, 09 Mar 2009 01:20:22 +1100, Sylvia Else wrote: > >> I've recently bought a D-Link DIR-300 wireless router. While >> disconnecting its power supply from it, I got a tingling sensation when >> I touched the plug (to be clear, I'm talking about the 5V DC plug, not >> the mains plug). >> >> An AVO meter shows about 90V AC to earth from either side of the 5V >> plug. Short circuit current to earth is about 0.1mA. >> >> Still, I thought these things were meant to be completely isolated. Has >> there been a change of approach? >> > > If the wart is 2-prong, turn it around in the socket. If it's 3-prong, > get an outlet tester. I can't really see how that could be relevant. If the device's low voltage side was completely isolated (which I've now learned it isn't), then changing the mains pins around wouldn't make any difference. Australia's power plugs cannot be reversed, even if they're only two prong. The sockets look like these: http://en.wikipedia.org/wiki/File:Wall_wart.jpg Sylvia.
Technical Details
Message-ID:
<00ba671c$0$7777$c3e8da3@news.astraweb.com>Path:
arc1-ca.pugleaf.net!g2news2.google.com!news2.google.com!newshub.sdsu.edu!news.astraweb.com!border1.newsrouter.astraweb.com!not-for-mailReferences:
<00b89736$0$7237$c3e8da3@news.astraweb.com> <pan.2009.03.09.20.20.12.51572@example.net>Show Full Headers
Complete Article Headers
X-Google-Thread: 112d1e,5985c699c60fb1f8 X-Google-Thread: 103407,5985c699c60fb1f8 X-Google-Attributes: gid112d1e,gid103407,domainid0,public,usenet X-Google-Language: ENGLISH,ASCII-7-bit Path: arc1-ca.pugleaf.net!g2news2.google.com!news2.google.com!newshub.sdsu.edu!news.astraweb.com!border1.newsrouter.astraweb.com!not-for-mail Date: Tue, 10 Mar 2009 10:20:26 +1100 From: Sylvia Else <sylvia@not.at.this.address> User-Agent: Thunderbird 2.0.0.19 (Windows/20081209) MIME-Version: 1.0 Newsgroups: sci.electronics.design,aus.electronics Subject: Re: Tingles from power supply References: <00b89736$0$7237$c3e8da3@news.astraweb.com> <pan.2009.03.09.20.20.12.51572@example.net> In-Reply-To: <pan.2009.03.09.20.20.12.51572@example.net> Content-Type: text/plain; charset=ISO-8859-1; format=flowed Content-Transfer-Encoding: 7bit Lines: 28 Message-ID: <00ba671c$0$7777$c3e8da3@news.astraweb.com> Organization: Unlimited download news at news.astraweb.com NNTP-Posting-Host: 91b81e79.news.astraweb.com X-Trace: DXC=`nbOgd3YS10fB5aLm@JgR<L?0kYOcDh@:mS<gX`XUL\1lBG8SDhF5o=[P0O7cFK0o9AJO\4<m0V`8YOI6H8W:LR>l@gV8R1F;l<