Article #85Re: is third transformer hole an earth?
From: ian field
Date: Wed, 12 Nov 2008 22:33
Date: Wed, 12 Nov 2008 22:33
271 lines
11887 bytes
11887 bytes
"Meat Plow" <meat@petitmorte.net> wrote in message news:2bcalk.4i2.17.4@news.alt.net... > On Wed, 12 Nov 2008 21:23:05 -0000, "ian field" > <gangprobing.alien@ntlworld.com>wrote: > >> >>"Meat Plow" <meat@petitmorte.net> wrote in message >>news:2bc3rq.btk.19.1@news.alt.net... >>> On Wed, 12 Nov 2008 14:50:28 -0000, "Arfa Daily" >>> <arfa.daily@ntlworld.com>wrote: >>> >>>> >>>>"Whiskers" <catwheezel@operamail.com> wrote in message >>>>news:slrnghlo20.bmt.catwheezel@ID-107770.user.individual.net... >>>>> On 2008-11-12, Arfa Daily <arfa.daily@ntlworld.com> wrote: >>>>>> >>>>>> "Whiskers" <catwheezel@operamail.com> wrote in message >>>>>> news:slrnghjjbg.e5j.catwheezel@ID-107770.user.individual.net... >>>>>>> On 2008-11-11, Arfa Daily <arfa.daily@ntlworld.com> wrote: >>>>>>>> "Whiskers" <catwheezel@operamail.com> wrote in message >>>>>>>> news:slrnghja8j.e5j.catwheezel@ID-107770.user.individual.net... >>>>>>>>> On 2008-11-10, Dave Plowman (News) <dave@davenoise.co.uk> wrote: >>>>>>>>>> In article >>>>>>>>>> <slrnghhb1o.bes.catwheezel@ID-107770.user.individual.net>, >>>>>>>>>> Whiskers <catwheezel@operamail.com> wrote: >>>>>>> >>>>>>> [...] >>>>>>> >>>>>>>> A system carrying a lot of amps to the load that's drawing it, is >>>>>>>> no >>>>>>>> more >>>>>>>> or >>>>>>>> less dangerous than one that's only carrying a small current, >>>>>>>> except >>>>>>>> in >>>>>>>> as >>>>>>>> much as there is a greater potential for heat failure at connection >>>>>>>> points >>>>>>>> within that system. A high voltage system, irrespective of how many >>>>>>>> amps >>>>>>>> it >>>>>>>> is capable of carrying above a few milliamps, is far more dangerous >>>>>>>> to >>>>>>>> a >>>>>>>> human, than a low voltage system good for a few hundred amps. Given >>>>>>>> the >>>>>>>> (reasonably) constant resistance of any described path through the >>>>>>>> human >>>>>>>> body, a voltage of a hundred volts with a current availability of >>>>>>>> as >>>>>>>> little >>>>>>>> as 50mA, may be enough to kill under the right (wrong!) >>>>>>>> circumstances. >>>>>>> >>>>>>> So a charge of 10kV from walking across a carpet (DC) , or a >>>>>>> "non-lethal" >>>>>>> 50kV "Tazer" (AC), are more dangerous than a 1kV power line? The >>>>>>> danger >>>>>>> from 'High Voltage' power lines comes from the vast amount of >>>>>>> current >>>>>>> they >>>>>>> can deliver. >>>>>> >>>>>> You see, there you go getting your apples and oranges mixed up again. >>>>>> A >>>>>> static charge from a carpet is not lethal to you because it is an >>>>>> extremely >>>>>> high resistance source. That is the nature of a static charge. No >>>>>> matter >>>>>> whether it is 1kV, 10kV or 40kV, the source resistance will ensure >>>>>> that >>>>>> only >>>>>> uA will flow for decimals of a uS. Enough to give you a nasty little >>>>>> crack, >>>>>> yes, but not enough to come within several orders of magnitude of >>>>>> being >>>>>> lethal. The same applies to the taser. It is designed to not be able >>>>>> to >>>>>> supply enough current (theoretically) to be lethal. However, its aim >>>>>> is >>>>>> to >>>>>> incapacitate by disrupting nerve activity and causing extreme pain. >>>>>> To >>>>>> do >>>>>> this, the charge is applied to the receiving body in multiple >>>>>> short-duration >>>>>> pulses. In some cases, this has proven to be fatal, I believe, due to >>>>>> the >>>>>> length of time that the pulses are delivered for. On the other hand, >>>>>> a >>>>>> high >>>>>> voltage power line, or even a fairly low voltage household supply, >>>>>> *is* >>>>>> potentially lethal not because it can deliver huge amounts of amps, >>>>>> but >>>>>> because the voltage that is present, is sufficient to drive *enough* >>>>>> (mili) >>>>>> amps from that low resistance source through the conduction path >>>>>> within >>>>>> the >>>>>> body. >>>>> >>>>> Precisely; it isn't the voltage that's lethal, it's the current. If >>>>> the >>>>> current isn't available, the voltage is pretty harmless. High-voltage >>>>> mains power lines carry a /lot/ of current, whereas high-voltage >>>>> 'Tazers' >>>>> don't. >>>>> >>>>>>>> On >>>>>>>> the other hand, a low voltage welding supply, will not have enough >>>>>>>> voltage >>>>>>>> behind it to push enough current through that same path to kill >>>>>>>> you, >>>>>>>> even >>>>>>>> though that supply is good for 200 amps or more. >>>>>>> >>>>>>> What voltage does a 'low voltage' welder operate at? Don't they use >>>>>>> capacitors to raise the supply voltage to at least 40kV? Or can >>>>>>> welding >>>>>>> really happen at 12V? >>>>>> >>>>>> Yes, arc welding can occur at 12v and, in fact, at lower voltages >>>>>> than >>>>>> this, >>>>>> although there are many different methods these days of generating >>>>>> and >>>>>> controlling the welding arc, though none that operate by charging >>>>>> caps >>>>>> to >>>>>> the sorts of voltages that you are talking about, as far as I am >>>>>> aware. >>>>>> In >>>>>> general, arc welding is a high current rather than high voltage >>>>>> system. >>>>>> Spot >>>>>> welders sometimes work by charging very large capacitors to low >>>>>> voltages. >>>>>> The reason that the low voltage arc welder is not capable of killing >>>>>> you, >>>>>> any more than a car battery can, is because although both are >>>>>> extremely >>>>>> low >>>>>> internal resistance sources, and hence capable of supplying large >>>>>> amounts >>>>>> of >>>>>> current to a low resistance load, the human body is a much higher >>>>>> resistance >>>>>> load, so the 12v is not capable of pushing enough miliamps through >>>>>> that >>>>>> path, to cause electrocution - or even electric shock. >>>>> >>>>> OK, I'm not familiar with arc welding, and I'm surprised that 12V is >>>>> enough to strike an arc. But your comment that it is the high current >>>>> that matters for creating a weld, rather supports my contention that >>>>> current is more dangerous than voltage. >>>>> >>>>> Electron beam welding (which you probaby won't find happening in a >>>>> garden >>>>> shed or on a building site) requires many thousand volts, but only a >>>>> small >>>>> current (less than 1A). >>>>> >>>>> The only welding I've ever done myself, involved a coke-burning forge >>>>> and >>>>> a heavy hammer. >>>>> >>>>>>>> As far as your contention that a transformer isolated supply is >>>>>>>> only >>>>>>>> safe >>>>>>>> with double insulated equipment, that simply isn't true. The only >>>>>>>> way >>>>>>>> that >>>>>>>> you can drive current through the body from such an isolation >>>>>>>> transformer, >>>>>>>> is to hang yourself across both output terminals. Either terminal >>>>>>>> to >>>>>>>> ground >>>>>>>> will present no electric shock hazard at all. >>>>>>>> >>>>>>>> Arfa >>>>>>> >>>>>>> Sounds too good to be true. >>>>>> >>>>>> Well, if you understood the principles of isolation transformers, >>>>>> which >>>>>> as >>>>>> well as being used on building sites for obvious reasons, are also to >>>>>> be >>>>>> found in every professional electronics workshop, to render safe, the >>>>>> need >>>>>> to work on live equipment employing such potentially lethal nasties, >>>>>> as >>>>>> switch mode power supplies, then you would know that it isn't too >>>>>> good >>>>>> to >>>>>> be >>>>>> true - it simply *is* true. Sketch it down on a piece of paper then >>>>>> have >>>>>> a >>>>>> good think about it. >>>>>> >>>>>> Arfa >>>>> >>>>> The only 'isolation transformers' I've come across, are earthed - and >>>>> either have an output restricted to 50V or less (that threshold at >>>>> which >>>>> the human body's resistance drops substantially) or provide a good >>>>> earth >>>>> connection for the appliance. An isolation transformer /does/ >>>>> disconnect >>>>> the connection that exists between the power station and the ground >>>>> and >>>>> is >>>>> carried by the 'live' or 'hot' cable, but that is /not/ the same as >>>>> the >>>>> safety 'earth' connection which is meant to provide a relatively safe >>>>> return path in case exposed metal parts of the appliance accidentally >>>>> become connected to the power supply. >>>> >>>> >>>>Neutral and ground are bonded together at the substation >>>> >>>> >>>>> >>>>> The 'earth' connection provided by an 'isolation transformer' to the >>>>> appliances running off it, may be arranged to effectively create a >>>>> 'short-circuit' on the output windings of the transformer if any >>>>> current >>>>> flows through it, and that should trigger the safety cut-off (probably >>>>> a >>>>> 'residual current device'). Or the 'earth' connection will pass >>>>> straight >>>>> through to the same 'earth' as the mains supply provides. >>>>> >>>>> A double-insulated appliance has no exposed metal parts that can >>>>> become >>>>> connected to the power supply, and that's why they are permitted to be >>>>> used with no 'earth'. >>>>> >>>>> -- >>>>> -- ^^^^^^^^^^ >>>>> -- Whiskers >>>>> -- ~~~~~~~~~~ >>>> >>>>Hmmmm. Your understanding of the principles of ground isolation by use >>>>of >>>>a >>>>transformer seem very flawed I'm afraid, as also is your knowledge of >>>>electricity distribution schemes, and earth / neutral commonality. >>>> >>>>Arfa >>>> >>> >>> Whiskers is an idiot from the 24hoursupport.helpdesk newsgroup. >>> Probably got trolled here by the Hucker idiot. >> >>PHucker usually hangs out on alt.binaries.chatter , I can't recall seeing >>whiskers there. PHucker sometimes trolls on the sci.electronics groups - >>usually asking stupid questions then criticizing the answers he's given. >> > > Lol yeah that pretty much sums it up. I think he's actually smart > enough to engage in some useful conversations should he choose to do > so. He claims to have a degree in physics, yet according to him he found physics too boring so he settled for a tech support job in a computer dept - funny how he visits this group yet never seems to contribute in any meaningful way.
Technical Details
Message-ID:
<UQISk.53128$Dk7.37455@newsfe30.ams2>Path:
arc1-ca.pugleaf.net!g2news1.google.com!news4.google.com!feeder.news-service.com!69.16.177.246.MISMATCH!cyclone03.ams.highwinds-media.com!news.highwinds-media.com!npeersf01.ams.highwinds-media.com!newsfe30.ams2.POSTED!7564ea0f!not-for-mailReferences:
<op.uke2nuxb4buhsv@fx62.mshome.net> <slrnghhb1o.bes.catwheezel@ID-107770.user.individual.net> <4ffc47586adave@davenoise.co.uk> <slrnghja8j.e5j.catwheezel@ID-107770.user.individual.net> <U3jSk.85501$i%.83610@newsfe25.ams2> <slrnghjjbg.e5j.catwheezel@ID-107770.user.individual.net> <7qrSk.8445$ji.2138@newsfe27.ams2> <slrnghlo20.bmt.catwheezel@ID-107770.user.individual.net> <W2CSk.67948$QF4.59449@newsfe13.ams2> <2bc3rq.btk.19.1@news.alt.net> <0PHSk.54310$Bk7.40254@newsfe29.ams2> <2bcalk.4i2.17.4@news.alt.net>Show Full Headers
Complete Article Headers
X-Google-Thread: 1131b0,8ae7935e94fea1ee X-Google-Thread: faa3c,8ae7935e94fea1ee X-Google-Attributes: gid1131b0,gidfaa3c,domainid0,public,usenet X-Google-Language: ENGLISH,ASCII-7-bit Path: arc1-ca.pugleaf.net!g2news1.google.com!news4.google.com!feeder.news-service.com!69.16.177.246.MISMATCH!cyclone03.ams.highwinds-media.com!news.highwinds-media.com!npeersf01.ams.highwinds-media.com!newsfe30.ams2.POSTED!7564ea0f!not-for-mail From: "ian field" <gangprobing.alien@ntlworld.com> Newsgroups: sci.electronics.repair,24hoursupport.helpdesk References: <op.uke2nuxb4buhsv@fx62.mshome.net> <slrnghhb1o.bes.catwheezel@ID-107770.user.individual.net> <4ffc47586adave@davenoise.co.uk> <slrnghja8j.e5j.catwheezel@ID-107770.user.individual.net> <U3jSk.85501$i%.83610@newsfe25.ams2> <slrnghjjbg.e5j.catwheezel@ID-107770.user.individual.net> <7qrSk.8445$ji.2138@newsfe27.ams2> <slrnghlo20.bmt.catwheezel@ID-107770.user.individual.net> <W2CSk.67948$QF4.59449@newsfe13.ams2> <2bc3rq.btk.19.1@news.alt.net> <0PHSk.54310$Bk7.40254@newsfe29.ams2> <2bcalk.4i2.17.4@news.alt.net> Subject: Re: is third transformer hole an earth? Lines: 273 X-Priority: 3 X-MSMail-Priority: Normal X-Newsreader: Microsoft Outlook Express 6.00.2900.2180 X-RFC2646: Format=Flowed; Original X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.2180 Message-ID: <UQISk.53128$Dk7.37455@newsfe30.ams2> NNTP-Posting-Host: 81.105.200.30 X-Complaints-To: http://netreport.virginmedia.com X-Trace: newsfe30.ams2 1226529204 81.105.200.30 (Wed, 12 Nov 2008 22:33:24 UTC) NNTP-Posting-Date: Wed, 12 Nov 2008 22:33:24 UTC Organization: virginmedia.com Date: Wed, 12 Nov 2008 22:33:18 -0000