Article View: sci.electronics
Article #14633Re: Basic bench equipment query
From: Bill Mayhew
Date: Mon, 21 Dec 1992 14:21
Date: Mon, 21 Dec 1992 14:21
33 lines
2107 bytes
2107 bytes
If you are going to do much digital work, you really should try to get a 100 Mhz - 150 MHz bandwidth scope. To make reasonably accurate rise time measurements, you need approximately 10 times input bandwidth versus the repetition rate of the signal. Yes, it is possible to compute rise times from a scope with a more limited bandwidth, but it is rather inconvenient and best left as an exercise for an engineering school measurement techniques course. I've got an old Tektronix 547 at home that has a less than 30 MHz bandwidth, but that is somewhat mitigated by having a 1S1 sampler plug-in unit for > 1 GHz sampling, but that is only useful for repetitive signals. Having extended bandwidth also assists greatly for spotting glitches in pulses. You'll definitely appreciate that if you do any fiddling around with digital stuff. I've had a Tek 2445 on my bench here at work for about 8 years now, and have been quite pleased with it. The 2445 doesn't have nearly the bells and whistles of some of the newer units, but it does have 150 MHz bandwidth, four inputs, triggered/delayed/intensified sweep and measurement cursors. I'd imagine that 2445s are probably starting to come down in price in the surplus market now. In the unlikely event a 2445 shows up at a hamfest, it is usually gone in a few minutes. By the way, if anybody has a working 1L5 spectrum analyzer plug-in to get rid of, I might be interested.... -- Bill Mayhew NEOUCOM Computer Services Department Rootstown, OH 44272-9995 USA phone: 216-325-2511 wtm@uhura.neoucom.edu (140.220.1.1) 146.580: N8WED
Technical Details
Message-ID:
<1992Dec21.142138.2576@uhura.neoucom.edu>Path:
arc1-ca.pugleaf.net!sparky!uunet!usc!zaphod.mps.ohio-state.edu!magnus.acs.ohio-state.edu!usenet.ins.cwru.edu!neoucom.edu!wtmReferences:
<BzB8rD.BDp@hfglobe.intel.com> <2B3582F9.18867@news.service.uci.edu>Show Full Headers
Complete Article Headers
Newsgroups: sci.electronics Path: arc1-ca.pugleaf.net!sparky!uunet!usc!zaphod.mps.ohio-state.edu!magnus.acs.ohio-state.edu!usenet.ins.cwru.edu!neoucom.edu!wtm From: wtm@uhura.neoucom.edu (Bill Mayhew) Subject: Re: Basic bench equipment query Message-ID: <1992Dec21.142138.2576@uhura.neoucom.edu> Organization: Northeastern Ohio Universities College of Medicine References: <BzB8rD.BDp@hfglobe.intel.com> <2B3582F9.18867@news.service.uci.edu> Date: Mon, 21 Dec 1992 14:21:38 GMT Lines: 33