I have a quibble here: In article <935@sdcc7.ucsd.EDU> muller@sdcc7.ucsd.EDU (Keith Muller) writes: > Although the capacitors >do lower ripple, they have terrible response to dynamic load swings... In the cases I have worked with, the capacitors actually have much better response to dynamic load swings than the rectifier-transformer-60Hz line behind them. The problem is that they can only store so much energy, so eventually they can no longer cover up the shortcomings of these other components. Jeff Winslow
Technical Details
Message-ID:
<1666@midas.TEK.COM>Path:
arc1-ca.pugleaf.net!utzoo!mnetor!uunet!seismo!mcnc!rutgers!ucla-cs!zen!ucbvax!decvax!tektronix!teklds!midas!jeffwReferences:
<5705@ut-ngp.UUCP> <1884@kitty.UUCP> <935@sdcc7.ucsd.EDU>Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: arc1-ca.pugleaf.net!utzoo!mnetor!uunet!seismo!mcnc!rutgers!ucla-cs!zen!ucbvax!decvax!tektronix!teklds!midas!jeffw From: jeffw@midas.TEK.COM (Jeff Winslow) Newsgroups: sci.electronics Subject: Re: Choosing Cap Size in Power Supply Message-ID: <1666@midas.TEK.COM> Date: Tue, 28-Jul-87 13:28:51 EDT Article-I.D.: midas.1666 Posted: Tue Jul 28 13:28:51 1987 Date-Received: Thu, 30-Jul-87 05:28:57 EDT References: <5705@ut-ngp.UUCP> <1884@kitty.UUCP> <935@sdcc7.ucsd.EDU> Reply-To: jeffw@midas.UUCP (Jeff Winslow) Organization: Tektronix, Inc., Beaverton, OR. Lines: 14