🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: sci.electronics
Article #6903

Re: AC power inverter questions?

#6903
From: Brian E Rhodefer
Date: Wed, 16 Sep 1992 02:12
13 lines
1094 bytes
In article <1992Sep15.121257.12932@aston.ac.uk> evansmp@uhura.aston.ac.uk (Mark Evans) writes:
>
>If you are using an inverter to power lighting then note that
>Flouresent tubes will run at a higher efficencency (produce more light)
>if they are run at a higher frequency.
>(several KHz is a usefull frequency)

Maybe so, but since `normal' flUOrescent fixtures use series inductance
to limit their operating current, it might be a tad hard to come up with
the kilovolt-range supply voltages required to run 'em at `several KHz'.