Hi, I have some questions regarding the quality of microplates for microscopy, mainly 96- and 384 well SBS-standard layout formats (1536 and 6144 layouts would be interesting too of course). I have been doing some quality tests for certain types of multiwell plates which are very popular for use in "readers" with our 40x 0.75 N.A. objective and a 63x 0.8 objective in brightfield and fluorescence. These objectives have a very good spatial resolution and capture a lot of light for weak fluorescence (I ~ N.A.^4/M^2). However these objectives have a short working distance and as such the quality of the plate bottoms is important. Our autofocus system only needs about 5 videoframes to gather enough information to find a focus level, so with a 40 millisec. frametime (PAL 25 fps.) and some time for mechanical movement, it does a complete image content based autofocus in 0.3 or 0.4 seconds (300 or 400 milliseconds). But this only is the case, when a focuslevel is found within a certain range, i.e. the travel range needed for 5 frames, which is in principle determined by the Nyquist sampling theorem for Z-slicing. We also do a complete range check, as we want to focus in those microscopy modes which can cause multiple maxima in a focus algorithm (patented) in which case we focus on the highest peak/score found ( Geusebroek J.M., Cornelissen F., Smeulders A. W. M., and Geerts H., Robust autofocusing in microscopy, Cytometry, 36(1):1-9, 2000 ). Using an image content based autofocus system, allows us to use very fine Z-level focusing into cells with a varying offset to the multiwell plate bottom. I found out that when you plot the bottom profile of standard multiwell plates as a 3D landscape, these plates look more than a mountaneous region than having a flat profile. I also found some microplate types with very thin plastic bottoms and a flat plate bottom, but they are of course a bit more expensive. Glass bottom plates are an alternative in some cases, but I heard that the glue which is used for these plate-bottoms is not compatible with some of the solvents used in farmaceutical research (DMSO, etc), so the bottoms tend to fall off the plate after 24 h. incubation, which would be rather inconvenient for our time-lapse work [:-(] ? So using good quality plastic bottom plates seems to be one possible solution ? A possible solution for the variability of the plate bottoms is to do a prescan at lower mag./N.A., either with a plate bottom finding laser-system or a content-based autofocus and model the plate with a mathematical model, but this takes time. Using Long Distance (L.D.) objectives is another possible solution, but these objectives have a lower N.A. and as such less spatial resolution, which hampers subcellular imaging and analysis. Also the reduced N.A. has a very dramatic efect on the amount of light captured by the objective (I ~ N.A.^4/M2) and we always do our image capturing in real-time, we just use very sensitive cameras which allow imaging without the need to integrate frames. The image capturing must be done at 40 msec. (PAL 25 fps.), which is important when doing large volumes of multiwell plates in our screenings. Using the 0.75 and 0.8 N.A. objective in combination with the ultrasensitive camera allows us to dilute reagents up to 1000x, which is very good for our assay costs when doing large screens of subcellular phenomena [:-)] I would like to know what is the experience of other researchers with the quality of multiwell plates on microscopes or similar (automated) readers ? Does anyone else uses high N.A. objectives on multiwell plates for screening ? As far as I understand the SBS-standards define XY-measures of multiwell plates, but leave the bottom offset and bottom thickness to the manufactureres of multiwell plates ? Best regards, Peter Van Osta
Technical Details
Message-ID:
<20031201.133934.1884661237.22523@rommel_cs.com>Path:
arc1-ca.pugleaf.net!archiver1.google.com!news2.google.com!news.maxwell.syr.edu!newsfeed.media.kyoto-u.ac.jp!easynet-melon!easynet.net!feed0.news.be.easynet.net!not-for-mailShow Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 106237,4ab0018e70cd130c,start X-Google-Attributes: gid106237,public X-Google-Thread: f8e22,4ab0018e70cd130c,start X-Google-Attributes: gidf8e22,public X-Google-ArrivalTime: 2003-12-01 04:39:46 PST Path: arc1-ca.pugleaf.net!archiver1.google.com!news2.google.com!news.maxwell.syr.edu!newsfeed.media.kyoto-u.ac.jp!easynet-melon!easynet.net!feed0.news.be.easynet.net!not-for-mail From: "Peter Van Osta" <pvosta_ROMMEL@rommel_cs.com> Subject: Autofocus blues on microplates Date: Mon, 01 Dec 2003 13:39:34 +0100 Newsgroups: sci.techniques.microscopy,bionet.cellbiol Reply-To: pvosta_ROMMEL@ROMMEL_cs.com Organization: Union Biometrica N.V., ESO Message-ID: <20031201.133934.1884661237.22523@rommel_cs.com> User-Agent: Pan/0.9.7 (Unix) Mime-Version: 1.0 Content-Type: text/plain; charset=ISO-8859-1 Content-Transfer-Encoding: 8bit Lines: 73 NNTP-Posting-Date: 01 Dec 2003 12:39:35 GMT NNTP-Posting-Host: 213.193.139.10 X-Trace: 1070282375 feed0.news.be.easynet.net 1113 [::ffff:213.193.139.10]:35561 X-Complaints-To: abuse@be.easynet.net