Article View: sci.techniques.microscopy
Article #4Re: Autofocus blues on microplates
From: Kevin Cunningham
Date: Mon, 01 Dec 2003 19:45
Date: Mon, 01 Dec 2003 19:45
86 lines
5933 bytes
5933 bytes
"Peter Van Osta" <pvosta_ROMMEL@rommel_cs.com> wrote in message news:20031201.133934.1884661237.22523@rommel_cs.com... > Hi, > > I have some questions regarding the quality of microplates for microscopy, > mainly 96- and 384 well SBS-standard layout formats (1536 and 6144 layouts > would be interesting too of course). > > I have been doing some quality tests for certain types of multiwell plates > which are very popular for use in "readers" with our 40x 0.75 N.A. > objective and a 63x 0.8 objective in brightfield and fluorescence. These > objectives have a very good spatial resolution and capture a lot of light > for weak fluorescence (I ~ N.A.^4/M^2). However these objectives have a > short working distance and as such the quality of the plate bottoms is > important. > > Our autofocus system only needs about 5 videoframes to gather enough > information to find a focus level, so with a 40 millisec. frametime (PAL > 25 fps.) and some time for mechanical movement, it does a complete image > content based autofocus in 0.3 or 0.4 seconds (300 or 400 milliseconds). > But this only is the case, when a focuslevel is found within a certain > range, i.e. the travel range needed for 5 frames, which is in principle > determined by the Nyquist sampling theorem for Z-slicing. > > We also do a complete range check, as we want to focus in those microscopy > modes which can cause multiple maxima in a focus algorithm (patented) in > which case we focus on the highest peak/score found ( Geusebroek J.M., > Cornelissen F., Smeulders A. W. M., and Geerts H., Robust autofocusing in > microscopy, Cytometry, 36(1):1-9, 2000 ). > > Using an image content based autofocus system, allows us to use very fine > Z-level focusing into cells with a varying offset to the multiwell plate > bottom. > > I found out that when you plot the bottom profile of standard multiwell > plates as a 3D landscape, these plates look more than a mountaneous region > than having a flat profile. > > I also found some microplate types with very thin plastic bottoms and a > flat plate bottom, but they are of course a bit more expensive. Glass > bottom plates are an alternative in some cases, but I heard that the glue > which is used for these plate-bottoms is not compatible with some of the > solvents used in farmaceutical research (DMSO, etc), so the bottoms tend > to fall off the plate after 24 h. incubation, which would be rather > inconvenient for our time-lapse work [:-(] ? So using good quality plastic > bottom plates seems to be one possible solution ? > > A possible solution for the variability of the plate bottoms is to do a > prescan at lower mag./N.A., either with a plate bottom finding > laser-system or a content-based autofocus and model the plate with a > mathematical model, but this takes time. > > Using Long Distance (L.D.) objectives is another possible solution, but > these objectives have a lower N.A. and as such less spatial resolution, > which hampers subcellular imaging and analysis. Also the reduced N.A. has > a very dramatic efect on the amount of light captured by the objective (I > ~ N.A.^4/M2) and we always do our image capturing in real-time, we just > use very sensitive cameras which allow imaging without the need to > integrate frames. The image capturing must be done at 40 msec. (PAL 25 > fps.), which is important when doing large volumes of multiwell plates in > our screenings. Using the 0.75 and 0.8 N.A. objective in combination with > the ultrasensitive camera allows us to dilute reagents up to 1000x, which > is very good for our assay costs when doing large screens of subcellular > phenomena [:-)] > > I would like to know what is the experience of other researchers with the > quality of multiwell plates on microscopes or similar (automated) readers > ? Does anyone else uses high N.A. objectives on multiwell plates for > screening ? As far as I understand the SBS-standards define XY-measures of > multiwell plates, but leave the bottom offset and bottom thickness to the > manufactureres of multiwell plates ? > > Best regards, > > Peter Van Osta One thing you need to consider is the thickness of the bottom of the specimen plate. The objective is designed for a .17 mm thickness in glass. In fact an old trick question is "What is the first element in a lens that uses cover glass?". The answer is the cover glass. It is critical for your lenses to have a .17 cover glass, particularly for the NA 0.80 objective. I might think of a plate maker that used .17 mm as the standard even if the item is made of plastic. Kevin Cunningham
Technical Details
Message-ID:
<1TMyb.23735$sb4.1285@newsread2.news.pas.earthlink.net>Path:
arc1-ca.pugleaf.net!archiver1.google.com!news1.google.com!sn-xit-02!sn-xit-01!sn-xit-08!supernews.com!newsfeed.news2me.com!elnk-nf2-pas!newsfeed.earthlink.net!stamper.news.pas.earthlink.net!newsread2.news.pas.earthlink.net.POSTED!f32db0a4!not-for-mailReferences:
<20031201.133934.1884661237.22523@rommel_cs.com>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 106237,4ab0018e70cd130c X-Google-Attributes: gid106237,public X-Google-Thread: f8e22,4ab0018e70cd130c X-Google-Attributes: gidf8e22,public X-Google-ArrivalTime: 2003-12-01 11:45:02 PST Path: arc1-ca.pugleaf.net!archiver1.google.com!news1.google.com!sn-xit-02!sn-xit-01!sn-xit-08!supernews.com!newsfeed.news2me.com!elnk-nf2-pas!newsfeed.earthlink.net!stamper.news.pas.earthlink.net!newsread2.news.pas.earthlink.net.POSTED!f32db0a4!not-for-mail From: "Kevin Cunningham" <smskjc@mindspring.com> Newsgroups: sci.techniques.microscopy,bionet.cellbiol References: <20031201.133934.1884661237.22523@rommel_cs.com> Subject: Re: Autofocus blues on microplates Lines: 88 X-Priority: 3 X-MSMail-Priority: Normal X-Newsreader: Microsoft Outlook Express 6.00.2800.1106 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2800.1106 Message-ID: <1TMyb.23735$sb4.1285@newsread2.news.pas.earthlink.net> Date: Mon, 01 Dec 2003 19:45:01 GMT NNTP-Posting-Host: 209.86.130.215 X-Complaints-To: abuse@earthlink.net X-Trace: newsread2.news.pas.earthlink.net 1070307901 209.86.130.215 (Mon, 01 Dec 2003 11:45:01 PST) NNTP-Posting-Date: Mon, 01 Dec 2003 11:45:01 PST Organization: EarthLink Inc. -- http://www.EarthLink.net