Article #47uVax II/BA23/BA123/RQDX/RX50 problem
From: Bob Hoffman
Date: Fri, 30 Oct 1992 20:01
Date: Fri, 30 Oct 1992 20:01
59 lines
2708 bytes
2708 bytes
I have a pair of VAXstation II/GPX systems that are acting
inconsistently. I have tried as many things as I can think of and
have not been able to solve the problem.
The problem in a nutshell: An Emulex diagnostic RX50 boots and runs
just fine on a BA23-packaged VSII/GPX with the RQDX3 at 760334 (the
second MSCP address). The BA123-packaged system doesn't even recognize
the RQDX3 at 760334 from the boot prompt (">>>") -- it returns error
41, "DEVASSIGN".
System configurations:
BA23-pkg system BA123-pkg system
--------------- ----------------
CPU KA630, M7606-EF KA630, M7606-EF
Mem 2 x 4MB 8MB + 4MB
Disk Emu QD32 + Fuji 2322 @ 772150 Emu QD21 + Maxt 4380E @ 772150
RQDX3 + RX50 @ 760334 RQDX3 + RD52, RD53, RX50 @ 760334
Tape none TQK/TK50
Video 8-plane QDSS 8-plane QDSS
On the BA23 system, I can say "b dub0" and it boots the Emulex
diagnostic RX50 fine. On the BA123, "b dub2" returns the DEVASSIGN
error. Thinking that there might be a problem with just the floppy,
I tried to boot the RD53 with "b dub0" but I get the same error.
When I boot Ultrix, I can access all of the drives on the RQDX3
without any problem.
I have tried the following:
- I switched CPUs thinking that the boot PROMs may be different.
They aren't -- no change.
- I switched RQDX3s. No change.
- I switched RX50s. No change.
- Noting that the drive signal distribution is different in the BA123,
I took a known-good BA23-style signal distribution board and jury-rigged
it into the BA123. No change.
- I swapped the addresses on the QD21 and the RQDX3. Now, when I do a
"b dua2", the floppy diskette boots! The Emulex diagnostic monitor
loads and gives me the EVM> prompt. I type "L FVDMS" to load the
MSCP diagnostic and I get "read error" from the floppy.
The next thing I am going to try is substituting all the drive cables,
but I have been fooling with this problem off and on for many months
and I think I may have already done that and forgotten about it.
If anyone can shed some light on this problem I would be most appreciative.
Thanks,
---Bob.
--
Bob Hoffman, N3CVL pitt!hoffman
Pitt Computer Science hoffman@cs.pitt.edu FAX: +1 412 624 8854
Technical Details
Message-ID:
<17198@pitt.UUCP>Path:
arc1-ca.pugleaf.net!sparky!uunet!pmafire!news.dell.com!natinst.com!cs.utexas.edu!zaphod.mps.ohio-state.edu!cis.ohio-state.edu!news.sei.cmu.edu!drycas.club.cc.cmu.edu!pitt.edu!pitt!hoffmanShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!pmafire!news.dell.com!natinst.com!cs.utexas.edu!zaphod.mps.ohio-state.edu!cis.ohio-state.edu!news.sei.cmu.edu!drycas.club.cc.cmu.edu!pitt.edu!pitt!hoffman Newsgroups: comp.sys.dec Subject: uVax II/BA23/BA123/RQDX/RX50 problem Message-ID: <17198@pitt.UUCP> From: hoffman@cs.pitt.edu (Bob Hoffman) Date: 30 Oct 92 20:01:39 GMT Sender: news@cs.pitt.edu Organization: Univ. of Pittsburgh Computer Science Lines: 59